FS18OR18 450/750-V
FS18OR18 450/750-V
Cca – s3, d1, a3 -According to European Construction Products Regulation CPR R (UE) n.305/11
Reaction to fire REGULATION 305/2011/EU and standard EN 50575
Cables suitable for power supply in buildings and other civil engineering works with the aim of limiting the production and spread of fire and smoke according to the class envisaged.
Compliant with the Construction Products Regulation (CPR)
- Standard : EN 50575:2014+A1:2016
- Class: Cca-s3, d1, a3
- Classification (CEI UNEL 35016): EN 13501-6
- Heat and smoke emission during flame development: EN 50399
- Vertical flame spread: EN 60332-1-2
- Corrosive and halogenated gases: EN 60754-2
Reference standard :
CEI 20-40 2014/35/UE 2011/65/CE
Cable description :
FLEXIBLE cables for power, signalling and control, insulated in PVC of S18 quality, sheathed in PVC of R18 quality, with special reaction to fire characteristics and conforming to the Construction Regulation (CPR)
Conductor :
Annealed red copper with flexible round cord CLASS 5
Core isolation :
Polyvinyl chloride (PVC) quality S18
Colours :
2x Brown / Blue
3G Blue/Brown / Yellow-Green
4G Brown / Black / Grey / Yellow-Green
5G Brown / Black / Grey / Blue / Yellow-Green
Outer sheath :
Polyvinyl chloride (PVC) sheathing, R18 quality.
Colore guaina :
Brown.
Labeling :
Stamping on insulation every 1 m.
Technical specifications :
Resistant to mechanical stress, fire and flame retardant, very low emission of halogens, fumes,
toxic and corrosive gases. Good behaviour at low temperatures, good flexibility, smoothness and excellent peelability. Good resistance to abrasion.
.
Rated voltage: Uo/U 300/500 V
Maximum operating temperature: 70° C
Minimum operating temperature: -15° C
Maximum short-circuit temperature: 160° C
Laying conditions :
Minimum installation temperature: 0°C
Recommended minimum bending radius: 4 times the cable diameter
Maximum recommended tensile stress: 50 N/mm² of section
Packaging :
Hanks 100 metres - Wooden reel - Cardboard / plastic reels
Applications :
Cables for the transport of energy and transmission of signals, suitable for fixed installation in indoor areas with dry or wet environments and in areas with fire hazards. Temporary laying in outdoor areas is also permissible. For laying in free air in pipes or ducts and in metal structures.

H03VV-F 300/300 V
H03VV-F 300/300 V
Reference standards :
CEI 20-20 /5 - CENELEC HD 21.5 S3 - CEI EN 60332-1-2 - 2011/65/CE - 2006/95/CE
Cable description :
Multicore energy cables, flexible, harmonised, with PVC insulation and sheathing
- No flame propagation
- Good flexibility
Conductor :
Annealed red copper with flexible round cord CLASS 5
Core isolation :
Polyvinyl chloride (PVC) TI2 quality
Core colour :
2x Brown / Blue
3x Yellow-Green / Brown / Blue
Sheath :
Polyvinyl chloride (PVC) coating TM2 quality.
Sheath colour :
Black - White - Grey RAL 7035
Technical specifications :
Rated voltage: Uo/U: 300/300 V
Maximum operating temperature: 60° C
Minimum operating temperature: -10° C
Maximum short-circuit temperature: 150° C
Installation conditions :
Minimum installation temperature: 5°C
Recommended minimum bending radius:
4 times the maximum outer diameter (fixed p.p.)
6 times the maximum outer diameter (movable p.p.)
Maximum recommended tensile stress 15 N/mm² of copper section
Packaging :
Hanks 100 metres - Wooden reel
Applications :
Cables suitable for mobile laying. Suitable for installation in domestic premises, kitchens and offices as well as in humid environments. Also suitable for supplying heating and kitchen appliances as long as not in contact with hot parts and not subject to radiation. Not permitted for use in industrial agricultural buildings or outdoors and for non-domestic mechanical tools.
| Conductor number
N° |
Nominal
section mmq
|
Approximate
conductor diameter mm
|
Average insulation thickness
mm |
Maximum external diameter
mm |
Approximate weight
Kg /km |
Electrical resistance at 20° C.
Maximum Ω/Km
|
|
2 x |
0,50 | 0,9 | 0,5 | 5,9 | 36 | 39 |
| 0,75 | 1,1 | 0,5 | 6,3 | 45 | 26 | |
|
3 G |
0,50 | 0,9 | 0,5 | 6,3 | 44 | 39 |
| 0,75 | 1,1 | 0,5 | 6,7 | 55 | 26 |
H03VVH2-F 300/300 V
H03VVH2-F 300/300 V
Reference standards :
CEI 20-20 /5 - CENELEC HD 21.5 S3 - CEI EN 60332-1-2 - 2011/65/CE - 2006/95/CE
Cable description :
Multicore energy cables, flexible, harmonised, with PVC insulation and sheathing
- No flame propagation
- Good flexibility
Conductor :
Annealed red copper with flexible round cord CLASS 5.
Core isolation :
Polyvinyl chloride (PVC) TI2 quality.
Core colour :
2x Brown/Blue
Sheath :
Polyvinyl chloride (PVC) coating TM2 quality - FLAT SHAPE.
Sheath colour :
Black - White - Grey RAL 7035
Technical specifications :
Rated voltage: Uo/U: 300/300 V
Maximum operating temperature: 60° C
Minimum operating temperature: -10° C
Maximum short-circuit temperature: 150° C
Installation conditions :
Minimum installation temperature: 5°C
Recommended minimum bending radius:
4 times the maximum outer diameter (fixed p.p.)
6 times the maximum outer diameter (movable p.p.)
Maximum recommended tensile stress: 15 N/mm² of copper section
Packaging :
Hanks 100 metres - Wooden reel
Applications :
Cables suitable for mobile laying. Suitable for installation in domestic premises, kitchens and offices as well as in humid environments. Also suitable for supplying heating and kitchen appliances as long as not in contact with hot parts and not subject to radiation. Not permitted for use in industrial agricultural buildings or outdoors and for non-domestic mechanical tools.
| Conductor number
N° |
Nominal
section mmq
|
Approximate
conductor diameter mm
|
Average insulation thickness
mm |
Maximum external diameter
mm |
Approximate weight
Kg /km |
Electrical resistante at 20° C.
Maximum Ω/Km
|
|
2 x |
0,50 | 0,9 | 0,5 | 5,9 | 27 | 39 |
| 0,75 | 1,1 | 0,5 | 6,3 | 35 | 26 | |
| 1 | 1,2 | 0,5 | 7 | 63 | 19,5 |
FFROR 300/500 V - 450/750 V
FFROR 300/500 V - 450/750 V
Reference standards :
CEI 20 – 20/5 - CEI 20 – 11 - CEI 20 - 29
Cable description :
Extremely flexible cables for use in office equipment or domestic applications as extension cables for large appliances, mobile appliances and uses subject to frequent movement.
Conductor :
Red copper flexible round cord CLASS 6.
Core isolation :
Polyvinyl chloride (PVC) compound TI2.
Core colour :
2x Brown / Blue
3G Blue / Brown / Yellow-Green
4G Brown/Black/Grey/Yellow-Green
Sheath :
Polyvinyl chloride (PVC) based compound quality TM2.
Sheath colour :
Orange
Technical specifications :
Extreme flexibility.
Rated voltage: Uo/U: 300/500 V (for 1 mmq conductors) - 450/750 V (for 1.5/2.5 mmq conductors)
Maximum operating temperature: 70° C
Minimum operating temperature: -10° C
Maximum short circuit temperature: 160° C
Installation conditions :
Minimum laying temperature: 0°C
Recommended minimum bending radius:
10 times the cable diameter for mobile laying, 4 times for fixed laying.
Maximum recommended tensile stress:
50 N/mm² total section of the copper for fixed laying.
Packaging :
Hanks 100 metres - Wooden reel.
Applications :
Extremely flexible cables for portable devices, household appliances, tool extensions.
Conductor numberN°
Nominalsection
mmq
Approximateconductor diameter
mm
Average insulation thickness mm
Maximum external diameter mm
Approximate weight Kg /km
Electrical resistance at 20° C.Maximum
Ω/Km
2 x
1 1,3 0,7 8,8 80 19,5 1,5 1,5 0,7 9,3 92 13,3 2,5 1,9 0,8 11 145 7,98
3 G
1 1,3 0,7 9,4 95 19,5 1,5 1,5 0,7 9,8 115 13,3 2,5 1,9 0,8 12 165 7,98
4 G
1 1,3 0,7 10 115 19,5 1,5 1,5 0,7 11 140 13,3 2,5 1,9 0,8 13 205 7,98
N°
section
mmq
conductor diameter
mm
mm
mm
Kg /km
Maximum
Ω/Km
2 x
3 G
4 G
H01N2-D 100/100 V
H01N2-D - 100/100 V
Reference standards
CEI 20-19 /6
HD 22.6
CEI EN 60332-1-2
2006/95/CE
2011/65/CE
Cable description
Harmonised rubber-sheathed super-flexible single-core power transmission cables for arc welding machines.
Conductor
Red copper flexible round cord CLASS 5
Colour
Black
Insulation
Gomma
Labeling
Stamping every 1m
Technical specifications
Resistant to oil, mechanical stress and abrasion, fire and flame retardant, resistant to continuous bending and twisting.
Very good flexibility and UV resistance
Rated voltage: Uo/U: 100/100 V
Maximum operating temperature: 85° C
Minimum operating temperature: -35° C
Maximum short circuit temperature: 250° C
Installation conditions
Minimum laying temperature: (mobile laying) -25°C a 85 °C
Recommended minimum bending radius: 6 times the cable diameter
Maximum recommended tensile stress: 50 N/mm² of section
Packaging
- Hanks 100 metres
- Wooden reel
Applications
Single-core cables suitable for mobile connections for the transmission of high currents from the electric welding device to the welding tool itself, thanks to their extreme resistance to movement and their excellent flexibility.
| Nominal
section N°x mmq |
Indicative
conductor diameter
|
Average thickness Insulation | Maximum outer diameter | Approximate weight
Kg/Km |
Electrical resistance at 20° C.
Maximum Ω/Km
|
| 1 x 10 | 3,9 | 2 | 10 | 175 | 1,91 |
| 1 x 16 | 5 | 2 | 10 | 220 | 1,21 |
| 1 x 25 | 6,6 | 2 | 13 | 310 | 0,78 |
| 1 x 35 | 7,7 | 2 | 14 | 415 | 0,554 |
| 1 x 50 | 9,4 | 2 | 17 | 560 | 0,386 |
| 1 x 70 | 11 | 2,4 | 19 | 780 | 0,272 |
| 1 x 95 | 12,5 | 2,6 | 21 | 1030 | 0,206 |
| 1 x 120 | 15,5 | 2,8 | 24 | 1305 | 0,161 |
| 1 x 150 | 15,5 | 3 | 26 | 1600 | 0,129 |
H07RN- F - 450/750 V
H07RN- F - 450/750 V Eca
According to European Construction Products Regulation CPR (EU) n.305/11
Reaction to fire REGULATION 305/2011/EU
Standard : EN 50575:2014+A1:2016 e EN 13501-6:2014 Class: Eca Classification (CEI UNEL 35016): EN 13501-6:2014 Vertical flame spread: EN 60332-1-2
Reference standards
CEI EN 60332-1
CEI EN 50255-2-21
CEI 20-19/4 HD 22.4 S4
CEI 20-107/2-21
2006/95/CE
2011/65/CE
Cable description
Harmonised flame retardant rubber insulated polychloroprene (neoprene) sheathed cables
with high resistance to water, mineral oils, industrial greases and average mechanical stress,
with good flexibility and good resistance to ozone and chemicals.
Conductor
Flexible bare copper CLASS 5
Insulation
Special elastomeric (rubber) EI4 quality
Core colour
2x Brown / Light Blue
3x Yellow-Green / Brown / Light Blue
4x Yellow-Green / Black / Grey / Brown
5x Yellow-Green / Black / Light Blue / Brown / Grey
Subsequent formations with numbered cores
*Also available without G/V
Sheath
Polychloroprene (Neoprene) with high mechanical properties
Sheath colour
Black
Labeling
White ink stamping on the conduit every 1 m
Technical specifications
Rated voltage: Uo/U: 450/750 V c.a. - 0.6 /1 kV c.c.
Maximum operating temperature: 60° C
Minimum operating temperature: -40° C (in assenza di sollecitazioni meccaniche)
Maximum short circuit temperature: 200° C
Installation conditions
Recommended minimum bending radius:
6 times the outside diameter of the cable for mobile laying
3 times the outside diameter of the cable for fixed laying (if < or = 12mm)
4 times the external diameter of the cable for fixed laying (if > 12mm)
Maximum recommended tensile stress:
15 N/mm2 section for mobile laying
50 N/mm2 of section for fixed laying
Packaging
Hanks 100 metres Wooden reel
Applications
Cables suitable for installation in dry, damp, wet and open areas, and in workshops with explosive atmospheres.
For supplying and connecting mobile and lifting equipment and/or similar systems.
Recommended for connections subject to medium mechanical stress: agricultural and industrial workshop equipment,
heating plates, large kettles, portable lamps, power tools such as drills, motors or transportable machines on construction sites or in agricultural applications. They can also be used in temporary
buildings or construction site huts.
Use is permitted up to 1,000 V AC in the case of protected fixed installation in pipes.
Mechanical protection is required when used in indirect underground installation (installation criteria for flexible cables).
UNIPOLAR Conductor numbern
NominalSection
Indicativeconductor diameter
Average thickness Insulation Maximum outer diameter Indicative weight Kg/km
Electrical resistance at 20° C.Maximum
1 x
1,5 1,5 0,8 7,1 51 13,3 2,5 2 0,9 7,9 67 7,98 4 2,5 1 9 92 4,95 6 3 1 9,8 121 3,3 10 4 1,2 11,9 186 1,91 16 5 1,2 13,4 256 1,21 25 5,9 1,4 15,8 368 0,780 35 7,3 1,4 17,9 485 0,554 50 8,9 1,6 20,6 668 0,386 70 10,5 1,6 23,3 905 0,272 95 12,20 1,8 26 1180 0,206 120 13,80 1,8 28,6 1460 0,161 150 15,40 2 31,4 1810 0,129 185 16,9 2,2 34,4 2165 0,106 240 19,5 2,4 38,3 2750 0,0801
BIPOLARI Conductornumber
n
Nominalsection
mmq
Approximateconductor diameter
mm
Average insulation thickness
mm
Maximum external diameter mm
Indicative weight Kg/km Electrical resistance at 20° C.Maximum
Ω/Km
2 x
1 1,3 0,8 10 93 19,50 1,5 1,5 0,8 11 115 13,30 2,5 1,9 0,9 13,10 165 7,98 4 2,5 1 15,20 225 4,95 6 3 1 16,80 300 3,30 10 4 1,2 22,60 550 1,91 16 5 1,2 25,70 740 1,21 25 6,2 1,4 30,70 1060 0,78
TRIPOLARI Conductornumber
n
Nominalsection
mmq
Approximateconductor diameter
mm
Average insulationthickness
mm
Maximum external diameter mm
Indicative weight Kg/km Electrical resistance at 20° C.Maximum
Ω/Km
3 G
1 1,30 0,8 10,70 120 19,5 1,5 1,50 0,8 12 150 13,30 2,5 2 0,9 13,50 200 7,98 4 2,50 1 14,90 295 4,95 6 3 1 16,20 380 3,30 10 4 1,2 18,20 675 1,91 16 5 1,2 20,60 950 1,21 25 6,20 1,4 24,50 1355 0,78 35 7,40 1,4 27,30 1765 0,554 50 8,90 1,6 31,20 2415 0,386 70 10,50 1,6 35,60 3230 0,272 95 12,20 1,8 40 4225 0,206 120 13,80 1,8 44,50 5190 0,161 150 15,40 2 49,50 6415 0,129 185 16,50 2,2 55,20 7700 0,106
QUADRIPOLARI Conductornumber
n
Nominalsection
mmq
Approximateconductor diameter
mm
Average insulationthickness
mm
Maximum external diameter mm
Indicative weight Kg/km Electrical resistance at 20° C.Maximum
Ω/Km
4 G
1 1,3 0,8 11,9 145 19,5 1,5 1,5 0,8 13,1 175 13,3 2,5 2 0,9 15,5 255 7,98 4 2,5 1 17,9 355 4,95 6 3 1 20 485 3,30 10 4 1,2 26,5 845 1,91 16 5 1,2 30,1 1185 1,21 25 6,20 1,4 36,6 1730 0,78
PENTAPOLARI Conductornumber
n
Nominalsection
mmq
Approximate conductor diameter
mm
Average insulation thickness
mm
Maximum external diameter mm
Indicative weight Kg/km Electrical resistance at 20° C.Maximum
Ω/Km
5 G
1 1,3 0,8 13,1 180 19,5 1,5 1,5 0,8 14,4 220 13,30 2,5 2 0,9 17 310 7,98 4 2,5 1 19,9 445 4,95 6 3 1 22,2 605 3,30 10 4 1,2 29,1 1035 1,91 16 5 1,2 33,3 1465 1,21 25 6,20 1,4 40,4 2145 0,78
MULTIPOLARI (anime numerate) Nominalsection
mmq
Approximateconductor section
mm
Average insulationthickness
mm
Maximum external diameter mm
Indicative weight Kg/km Electrical resistance at 20° C.Maximum
Ω/Km
7 G 1,5 1,5 0,8 17,2 355 13,3 7 G 2,5 2 0,9 20 495 7,98 12 G 1,5 1,5 0,8 22,4 505 13,3 12 G 2,5 2 0,9 26,2 710 7,98 19 G 1,5 1,5 0,8 26,3 725 13,3 19 G 2,5 2 0,9 30,9 1035 7,98 24 G 1,5 1,5 0,8 30,7 915 13,3 24 G 2,5 2 0,9 36,4 1325 7,98
n
Section
conductor diameter
Kg/km
Maximum
1 x
number
n
section
mmq
conductor diameter
mm
thickness
mm
mm
Maximum
Ω/Km
2 x
number
n
section
mmq
conductor diameter
mm
thickness
mm
mm
Maximum
Ω/Km
3 G
number
n
section
mmq
conductor diameter
mm
thickness
mm
mm
Maximum
Ω/Km
4 G
number
n
section
mmq
conductor diameter
mm
thickness
mm
mm
Maximum
Ω/Km
5 G
section
mmq
conductor section
mm
thickness
mm
mm
Maximum
Ω/Km
FLEX INTERCOM NPI
FLEX INTERCOM NPI
Eca - According to European Construction Products Regulation CPR (EU) n.305/11
Reaction to fire REGULATION 305/2011/EU
- Standard : EN 50575:2014+A1:2016 e EN 13501-6:2014
- Class: Eca
- Classification (CEI UNEL 35016): EN 13501-6:2014
- Vertical flame spread: EN 60332-1-2
Test methods :
- CEI EN 60332-1-2:2006/A1:2016
- CEI EN 60332-1-1:2006/A1:2016
- EN 60332-1-2:2004/A11:2016
- EN 60332-1-1:2004/A1:2015
Reference standards :
CEI 20-22 - CEI 79-1 - IEC 332-15
Cable description :
Fire retardant signalling and control cables, with outer jacket and PVC compound inner insulation.
Cable suitable for intercom, electronics and computer systems.
Conductor :
Annealed red copper with flexible round cord.
Core isolation :
Polyvinyl chloride (PVC) TI2 quality.
Core colour :
Brown / Blue / Yellow / Green / Black / Grey / Orange / Pink
Red / White / Purple / Light Green / Light Yellow / Light Brown / Light Blue
Sheath :
Polyvinyl chloride (PVC) sheathing quality TM2.
Sheath colour :
Grey RAL 7035
Labeling :
Stamping on insulation every 1m.
Technical specifications :
Rated voltage: Uo/U: 300/300 V
Test voltage: 1500 V
Maximum operating temperature: 70° C
Minimum operating temperature: -10° C
Installation conditions :
Recommended minimum bending radius: 15 times the cable diameter
Packaging :
Hanks 100 metres - Wooden reel
| Conductor number
N°
|
Nominal
section mmq |
Approximate
conductor diameter mm
|
Average insulation thickness
mm |
Maximum external diameter
mm |
Indicative weight
Kg/km |
Electrical resistance at a 20° C.
Maximum Ω/Km
|
| 2 | 0,50 | 1,85 | 0,5 | 4,5 | 31 | 39 |
| 4 | 0,50 | 1,85 | 0,5 | 5,3 | 48 | 39 |
| 6 | 0,50 | 1,85 | 0,5 | 6,3 | 70 | 39 |
| 8 | 0,50 | 1,85 | 0,5 | 7,5 | 88 | 39 |
| 10 | 0,50 | 1,85 | 0,5 | 8,2 | 121 | 39 |
| 12 | 0,50 | 1,85 | 0,5 | 8,5 | 127 | 39 |
| 14 | 0,50 | 1,85 | 0,5 | 8,9 | 146 | 39 |
250/250 V FLEX PERMUTATOR
250/250 V FLEX PERMUTATOR
References standard :
CEI 20-11 - CEI 20-35 - CEI 20-22 II - CEI 46-5
Cable description :
Cables for plant connections with internal conductors insulated with PVC compound. Used wherever it is necessary to connect civil and industrial machines and systems.
Conductor :
Annealed red copper with flexible round cord.
Core isolation :
Polyvinyl chloride (PVC) TI2 quality.
Core colour :
Brown / Blue / Yellow / Green / Black / Grey / Orange / Pink
Red / White / Purple / Light Green / Light Yellow / Light Brown / Light Blue
Sheath :
Unsheathed cable.
Technical specifications :
Rated voltage: Uo/U: 250/250 V
Test voltage: 1500 V
Maximum operating temperature: 70° C
Minimum operating temperature: -10° C
Installation conditions :
Recommended minimum bending radius: 15 times the cable diameter.
Packaging :
Hanks 100 metres - Wooden reel
| Conductor number
N°
|
Nominal
section mmq |
Approximate
conductor diameter mm
|
Average insulation thickness
mm |
Maximum external diameter
mm |
Indicative weight
Kg/km |
Electrical resistance at a 20° C.
Maximum Ω/Km
|
| 2 | 0,50 | 1,85 | 0,5 | 4,5 | 31 | 39 |
| 4 | 0,50 | 1,85 | 0,5 | 5,3 | 48 | 39 |
| 5 | 0,50 | 1,85 | 0,5 | 5,8 | 60 | 39 |
| 6 | 0,50 | 1,85 | 0,5 | 6,3 | 70 | 39 |
| 7 | 0,50 | 1,85 | 0,5 | 6,9 | 79 | 39 |
| 8 | 0,50 | 1,85 | 0,5 | 7,5 | 88 | 39 |
| 10 | 0,50 | 1,85 | 0,5 | 8,2 | 121 | 39 |
| 12 | 0,50 | 1,85 | 0,5 | 8,5 | 127 | 39 |
| 14 | 0,50 | 1,85 | 0,5 | 8,9 | 146 | 39 |
DOUBLE TELEPHONE SWITCH
DOUBLE TELEPHONE SWITCH
Reference standards :
CEI 20-20
Cable description :
Cables for telephone equipment connections, transmission and patching in telephone exchanges.
Conductor :
Made of annealed red copper with rigid round cord - approximate conductor diameter 0.60 mm.
Core isolation :
Polyvinyl chloride (PVC).
Core colour :
Red / White
Sheath :
Unsheathed cable.
Technical specifications :
Nominal cross-section: 2 x 0,30 mmq
Test voltage: 1000 V c.a.
Maximum operating temperature : 80° C
Minimum operating temperature: -10° C
Installation conditions :
Fixed
Packaging :
Coils 100 / 250 / 500 metres - Cardboard / plastic reels
ALARM CABLE
ALARM CABLE
Eca In accordance with the European Construction Products Regulation CPR (EU) n.305/11
Reaction to fire REGULATION 305/2011/UE :
- Standard : EN 50575:2014+A1:2016 e EN 13501-6:2014
- Class: Eca
- Classification (CEI UNEL 35016): EN 13501-6:2014
- Vertical flame spread: EN 60332-1-2
Test methods :
- CEI EN 60332-1-2:2006/A1:2016
- CEI EN 60332-1-1:2006/A1:2016
- EN 60332-1-2:2004/A11:2016
- EN 60332-1-1:2004/A1:2015
Reference standards :
CEI 20-29 IEC 60228 - CEI 20-11 - CEI 20-35 IEC 60332.1 - CEI 20-22 II IEC 60332.3 - CEI 20/37 IEC 61034-2 - CEI UNEL 36762
Cable description :
Shielded cables suitable for connecting alarm and burglar alarm systems in residential and public areas.
The shielding is necessary due to the signal being transmitted at very low frequencies.
Conductor :
Flexible copper CLASS 5, concentric layers stranded.
Core isolation :
Polyvinyl chloride (PVC) R2 quality.
Core colour :
Brown / Blue / Yellow / Green / Black / Grey / Orange / Pink
Red / White / Purple / Light Green / Light Yellow / Light Brown / Light Blue
Shield :
100% coverage. Aluminium/polyester tape overlaid with flexible red copper continuity conductor
Sheath :
Polyvinyl chloride (PVC) sheathing RZ quality flame retardant
Colour sheath :
White / Grey RAL 7035
Labeling :
Stamping on conduit every 1m.
Technical specifications :
Operating voltage : 300/500 V
Test voltage: 4000 V c.c.
Maximum operating temperature: 70° C
Minimum operating temperature: -10° C
Installation conditions :
Recommended minimum bending radius: 10 times the cable diameter
Packaging :
Hanks 100 metres - Wooden Reel - Cardboard/plastic reels
| Conductor
number n |
Nominal
section mmq |
Aproximate conductor
diametere mm |
Average insulation
thickness mm |
Maximum external diameter
Mm |
Indicative weight Kg/km | Electrical resistance at a 20° C.
Maximum Ω/Km
|
| 2x 0,22+T | 0,22 | 0,7 | 0,4 | 3,6 | 18 | 0,22 – 90 |
| 4x 0,22+T | 0,22 | 0,7 | 0,4 | 4,2 | 27 | 0,22 – 90 |
| 6x 0,22+T | 0,22 | 0,7 | 0,4 | 5 | 38 | 0,22 – 90 |
| 8X 0,22+T | 0,22 | 0,7 | 0,4 | 5,5 | 44 | 0,22 – 90 |
| 2X 0,22+ 2X 0,50+T | 0,50 | 0,9 | 0,5 | 5 | 38 | 0,50 - 39 |
| 4X 0,22+ 2X 0,50+T | 0,50 | 0,9 | 0,5 | 5,5 | 44 | 0,50 – 39 |
| 6X 0,22+ 2X 0,50+T | 0,50 | 0,9 | 0,5 | 5,8 | 52 | 0,50 – 39 |
| 8X 0,22+ 2X 0,50+T | 0,50 | 0,9 | 0,5 | 6,2 | 56 | 0,50 – 39 |
| 10X 0,22+ 2X 0,50+T | 0,50 | 0,9 | 0,5 | 6,6 | 61 | 0,50 - 39 |
| 2X 0,22+ 2X 0,75+T | 0,75 | 1,1 | 0,5 | 5,5 | 45 | 0,75 - 26 |
| 4X 0,22+ 2X 0,75+T | 0,75 | 1,1 | 0,5 | 5,8 | 49 | 0,75 – 26 |
| 6X 0,22+ 2X 0,75+T | 0,75 | 1,1 | 0,5 | 6 | 52 | 0,75 – 26 |
| 8X 0,22+ 2X 0,75+T | 0,75 | 1,1 | 0,5 | 6,5 | 62 | 0,75 – 26 |