TWISTED VIDEO INTERCOM
Eca - In accordance with European Construction Products Regulation CPR (EU) n.305/11
Reaction to fire REGULATION 305/2011/EU
- Standard : EN 50575:2014+A1:2016 e EN 13501-6:2014
- Class: Eca
- Classification (CEI UNEL 35016): EN 13501-6:2014
- Vertical flame spread: EN 60332-1-2
Test methods :
- CEI EN 60332-1-2:2006/A1:2016
- CEI EN 60332-1-1:2006/A1:2016
- EN 60332-1-2:2004/A11:2016
- EN 60332-1-1:2004/A1:2015
Reference standards :
EN 50575 - EN 60811 - EN 50289 - EN 50290 – EN 60228 – EN 50265-2-1 - EN 50395 – EN 50396
Cable description :
Cable used for video door entry systems, suitable for distributing power and operating signals to all BUS devices in the system. Installation must be carried out with fixed internal laying on masonry and metal structures, using passages on pipes, gangways or channels. It is not suitable for passage with underground ducts.
Conductor :
Made of annealed red copper with flexible round cord..
Core isolation :
Polyvinyl chloride (PVC) R2 quality.
Core colour :
White / Blue
Sheath :
Polyvinyl chloride (PVC) sheathing RZ quality flame retardant
Sheath colour :
Green / Brown / White / Yellow
Labeling :
Stamping on conduit every 1 m.
Technical specifications :
Insulation voltage: 400 V
Maximum operating temperature: 70° C
Minimum operating temperature: -15° C
Installation conditions :
Recommended minimum bending radius: 10 times the cable diameter
Packaging :
Hanks 100 metres – Wooden reel – Cardboard/plastic.
Conductor number
N°
|
Nominal
section mmq |
Indicative diameter
mm |
Indicative weight
Kg/km |
Electrical resistance at 20° C.
Maximum Ω/Km
|
2 |
0,50 | 4,9 | 20 | 37,7 |
1 | 6,9 | 45 | 18,9 |